26 27
www.valcom.com • 800-825-2661
System Enhancements
STROBES - RINGERS - DISCREET COMMUNICATIONS
• For Security/Priority - A Tone May Be Better Than Voice
• Use In Hospitals - When Voice Announcements Are Not Appropriate
• Use In Department Stores - For Discreet Paging
Ringer Horns
Loud Warble Horn .............. V-9925A
•
90VAC Ring or 18VAC Buzzer Voltage Activation
• Connects Directly to PBX Station
• Built-In Tone Generator, 5-Watt Amplifier,
& Volume Control
Power Requirements: -24Vdc, 500mA Activate with 90Vac, 18Vac
6.5”H x 8.2”W x 10.4”D (16.51cm x 20.82cm x 26.4cm) 4.7 lbs (2.13 kg)
Loud Ringer & Warble Horn ........................ V-9945A
• Interrupted or Uninterrupted
Contact Closure Activation
• Built-In Tone Generator, 5-Watt Amplifier,
& Volume Control
• Warble Tone - Night Ring
• Single Tone - Time Clock/Doorbell Alarm
• Single Tone Overrides Warble Tone
if Activated Simultaneously
• CE
•
Power Supply Included
6.5”H x 8.2”W x 10.4”D (16.51cm x 20.82cm x 26.4cm) 5.4 lbs (2.45 kg)
s s
- 10
ADA Compliant Strobe .................. V-5580041
110 Candela of Brilliancy Strobe,
Covers 70 ft by 70 ft Area
•
Fits Into A Standard 4” X 4” Electrical Box (Included)
•
Can Be Activated By Applying Power, Dry Contact Closure
Or 70 Volt Speaker Voltage
•
Flash Rate Is Designed To Comply With ADA
•
Power Supply Included
•
Mount Strobe 80 Inches Above Floor
CAUTION: DO NOT Use 2 Strobes Within Same Field of View
4.25"H x 4.25"W x 4.25"D (10.80cm x 10.80cm x 10.80cm) 3.00 lbs (1.35 kg)
Auxiliary Relay Unit..............................................V-9955
Relay Unit for Strobe Activation,
Door Control, Camera Control
•
Three 24 VDC 2 Pole Relays w/1 Amp Contacts
•
Screw Terminals for All Connections
• Independent Control or Simultaneous Operation of Relays
• Expandable to 6 Relays by Adding V-9957 Expansion Board
7.1”H x 4.7”W x 2.1"D (18.03cm x 11.94cm x 5.33cm) 0.7 lbs (32 kg)
s s
Strobes
NEW
NEW
0
Power
Included
Adds Tones Over Paging
Multi-Tone Generator ..........................V-9927A
Up To 8 Different Tones w/A Single Unit
- Siren Evacuation* - Burst Alarm Signal*
- Whoop Tornado* - Chime Doorbutton/Code Call
- Warble Fire* - Dual Chime Doorbell Ring
- Steady Shift Changes* - TeleBell Auxiliary Ring
* USA Standard Immediate Evacuation Signals
• Contact Closure Activation
• Automatically Overrides Page or Music
• Choice of 2 Sets of 8 Different Tones • CE
Specifications: Input Impedance: 600ohm; Output: 8ohm Power Requirements: -24Vdc, 65mA
8.2”H x 4.55”W x 2.3”D (20.82cm x 11.5cm x 5.84cm) 1.8 lbs (.82 kg)
6 Line Audible Ring Unit ................V-9936A
• 90Vac Ring or Dry Contact Closure Activation
• Connects Directly up to 6 C.O. or PBX Station Lines
• Ringing Over Paging Speakers
• Contact Closure Output to Activate Loud Bells
• Automatically Overrides Page or Music
• Built-In Warble Tone Generator
Specifications: Output: 8 ohm Power Requirements: -24Vdc, 200mA
8.2”H x 4.55”W x 2.3”D (20.82cm x 11.5cm x 5.84cm) 1.9 lbs (.86 kg)
C.O. Audible Ringer ........................... V-9924C
• 90Vac, 18Vac, or Dry Contact Closure Activation
• Connects to Analog PBX Station Port
• Ringing Over Paging Speakers
• Provides 3 Separate Zone Outputs & Volume
Controls for Use w/One-Way or Talkback Page Controls
• Automatically Overrides Page or Music
Power Requirements: -24Vdc, 300mA
8.2”H x 4.55”W x 2.3”D (20.82cm x 11.5cm x 5.84cm) 1.7 lbs. (.77 kg)
Code Call Unit.................... ..........................V-9923B
• For Security/Priority - A Tone May Be Better Than Voice
• Use In Hospitals
- When Voice Announcements Are Not Wanted
• Use In Department Stores
- Does Not Distract Customers
• Contact Closure Output to Activate Loud Bells
•
Up to 81 Two-Digit Codes or 729 Three-Digit Code
s
Power Requirements: -24Vdc, 300mA • CE
7.1"H x 5.9"W x 2.1"D (18.03cm x 14.99cm x 5.33cm) 1.9 lbs (.77 kg)
s s s s
Hear It
On
The Web!
- 2
- 4
- 6
- 6
0
Comentarios a estos manuales