Features
• 19 stations or zones
• Built-in talkback amplifier for handsfree talkback
operation (V-119RTHF)
• Dial tone
• Ringback tone
• Last number dialed re-ring (tone only)
• Conference calling on tone dial systems (handset to
handset only)
• Personal signaling (tone only)
• Combined rotary and tone dialing
• Speaker inhibit (with 1A2 key systems)
• Splash tone (V-119RTHF only)
• 15 second repeat alert tone option
• Optional all call (requires V-1118 one-way all call
unit)
Capacity
• The capacity of the V-119RTVA or V-119RTHF is
19 zones or stations.
• One talkpath.
• The maximum number of speakers on a zone is two
45 ohm talkback (V-119RTHF) or 40 one-way
amplified speaker assemblies (V-119RTVA).
Numbering Plan
• The dialing codes are: 0, 1, 3-9, 20-29.
System Configuration
• For talkback, use the V-119RTHF and 45 ohm
talkback speakers (maximum two per zone).
• For one-way voice announce, use the V-119RTVA
with one-way amplified speakers (maximum 40 per
zone).
NOTE: One-way amplified speakers may also be
used with the V-119RTHF in areas where talkback is
not required.
Dimensions/Weight
•
7.1" H x 5.9" W x 2.1" D
(18.03 cm x 14.99 cm x 5.33 cm)
• 3.5 lbs. (1.6 kg)
Power Requirements
Voltage Working Limits Current
Talk battery –21.5 to –26 Vdc 60 mA
Signal battery –21.5 to –26 Vdc 250 mA
Lamp battery 9V to 11 Vac 45 mA
per lamp
Electrical Characteristics
Parameters Working Limits
Input Imp. T and R 600 Ohm (incl.inst.)
Max. Cable Length
One-Way Page 5000 Feet
Talkback Page 800 Feet
Dial Pulses 8-12 PPS
60-40 Break ratio
+10%
Tone Signals Industry Standard
Frequency
Bandwidth 3%
Twist 6db
Detect 40 MS
Interdigital Time 40 MS
Environmental
Temperature 0/ to 50/ C
Humidity 0/ to 85/ Non-precip.
INSTALLATION
These instructions cover only the installation
procedures for the Valcom V-119RTVA and
V-119RTHF. Consult the installation instructions for
other equipment that may be used. Installation
procedures are the same for the V-119RTVA and
V-119RTHF.
Precautions
All precautions have been taken at the factory to
insure that the equipment functions properly. To
insure proper operation and to prevent equipment
damage, please observe the following:
• Unplug the power supply before making any
connections to the control unit.
• Do not locate the control unit closer than 18
inches or farther than 5 feet from the power
supply.
• Do not use a lamp tester to check signals, use a
voltmeter. A lamp tester when first applied is a
short circuit to electronic circuits.
• Do not apply power to the control unit until all
connections have been double-checked.
Mounting
Mount the V-119RTVA or V-119RTHF on a 7" KTU
mounting, relay rack, or on the wall.
Connections
__ 1. Fasten a 25 pair female amphenol ended
cable to the unit and terminate all leads on a
66 type block.